Maintenance

3. For the M and L group pumps, tighten the jacking screws (418) until the gap between the

clamp ring (141C) and the C-face motor support and bearing frame is 3.50 in. (8.89 cm).

4. For all pumps except the V group, grasp the suction flange of the casing and pull the

casing-liquid end free from the magnet assembly.

5. For all pumps except the SP group, remove the casing bolts (356A).
6. Wrap a piece of emery cloth around the containment shell (750) and secure it with a large

hose clamp.

Figure 20: V group

Figure 19: SP group

Figure 21: XS, X, S, M, and L groups

7. Disassemble the containment shell:

a) Screw the C-face motor support and bearing frame bolts (370B) into the tapped holes

of the clamp ring (141C) and tighten evenly in order to remove the containment shell.

b) Remove the O-ring (412M) from the containment shell (750) and discard it.
c) Remove the hose clamp and emery cloth.