14. For the 3298 and V3298, install these items into the casing:

a) Install the containment shell and impeller assembly into the casing (100). Use care that

the O-ring (412M) remains in place.

b) Install the clamp ring (141C) into the casing (100) with the hex capscrews (356A).

Figure 55: 3298 XS, S, M, and L groups

Figure 56: V3298

3298 Family Installation, Operation, and Maintenance Manual