Tility, Equirements, Onnections – Glastender GW24 User Manual

Page 4: Ncrating, Ssembly, Nstructions

Advertising
background image

2

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780

800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com

The glasswasher is shipped in one carton. Refer to the images on the opposite page to identify the following:

1. Main section

2. Drainboard insert

3. Drainboard pan

4. Sliding cover

5. Inner cover

u

tIlIty

r

equIrements

and

c

onnectIons

1. G

eneral

p

lumbInG

(Hot and cold water

required)

a. Use 1/2" OD (or larger) copper to 3/8" FMPT adapter provided.

b. Minimum water pressure - 25 PSI.

c. Maximum water pressure - 100 PSI. Install water pressure regulator if line pressure is over

100 PSI. Water valve on unit has built-in strainer and flow control to provide consistent vol-

ume between 25 and 100 PSI.

d. Install separate water shut-off valve for each connection.

e. Unit has built-in air gaps - vacuum breakers NOT required.

2. h

ot

W

ater

W

ash

a. Maximum temperature 150°F (66°C). Minimum supply temperature 130°F (54°C) to ensure

a minimum wash temperature of 120°F (49°C).

3. c

old

W

ater

r

Inse

a. No minimum cold water inlet temperature. Control module automatically tempers rinse

based on temperature setting (see Start-Up Instructions page 5, Step 5).

2. d

raIn

a. 1-1/2" tailpiece provided on unit.

b. Use open type floor drain for maximum drainage.

3. e

lectrIcal

a. 120V, single phase, 60Hz, 6-foot grounded cord included.

b. A dedicated 15 amp circuit is recommended.

c. Power requirements - 3.5 amps.

4. d

eterGent

a. Extra heavy-duty non-foaming commercial liquid dish detergent required. Adjust to .30% con-

centration.

b. Consult The local chemical supplier to match detergent with local water conditions.

5. s

anItIzer

a. Liquid chlorine bleach (sodium hypochlorite - 5.25% solution) adjusted to 50 PPM.

6. r

Inse

a

Id

a. Liquid Rinse Aid adjusted for proper sheeting.

7. n

otes

a. In all cases, consult local plumbing, electrical, and health codes for regulations which may

not be consistent with the above.

b. Utility connections are made up from the floor at the bottom of the unit approximately 6" high.

c. A side notch located on the left side of the unit provides space for three one-gallon chemical

containers within the 24" x 24" footprint.

6. Conveyor

7. Spray box

8. Spray box gasket

9. Tank screen

10. Drain stopper

u

ncratInG

and

a

ssembly

I

nstructIons

11. Inlet screen

12. Scrap tray

13. Water inlets

14. Chemical inlets

a

ssembly

p

rocedures

:

1. Remove all packaging from the main section.

2. Remove plastic protective paper from all stainless steel parts.

3. Place glasswasher in position and level by adjusting the bottom portion of the stainless legs.

4. Make plumbing connections in accordance with utility requirements listed above.

5. Install chemical bottle rack accessory if ordered with unit. See page 10 for installation instructions.

Advertising