10

7. Cold Control Adjustment:

8. s

ystem

s

tart

-

uP

:

It is a good practice to operate the glycol recirculation system for sixty (60) minutes before run-
ning beer through to the remote dispensing station(s). This enables the glycol circuit to be checked
for leaks. Also, recirculating cold glycol through the lines enables the temperature inside the trunk
line to stabilize before beer is introduced.


• Once the refrigeration unit and the glycol recirculating pump have operated for sixty (60)

minutes or more, the beer product can be connected and drawn through the trunk line

• Check the system for leaks.

• Thoroughly insulate all line joints in the trunk line and dispensing station(s).

NOTE: Be certain to close off the trunk line end with insulating tape at the point where

the glycol recirculating lines enter, otherwise condensation will occur on exposed

lines.

Scale

Adjusting Knob

Cold Control

c

olD

c

ontrol

a

Djustment

anD

s

ystem

s

tart

-u

P