3

lc86 s

Pecifications

S

tanDarD

F

eatures

• Modular lift-out refrigeration system for easy

in- field service

• High capacity refrigeration and recirculation for

high volume and remote long distance installations

• CFC-free R134a refrigerant

• Light-weight, roto-molded glycol bath with drain

• Polyurethane foamed-in-place insulation
NOTE: Clearance of 12” required around unit for

maximum air flow and 20” of overhead

clearance for servicing compressor.

Dimensions

• Height - 24.25” (61.6 cm)

• Width - 26.75” (67.9 cm)

• Depth - 16.50” (41.9 cm)

Electrical

• 115V, 1 phase, 60 Hz, 16.0 full load amps

• 230V, 1 phase, 50 Hz, 8.0 full load amps

• Dedicated 20 amp circuit is required

• Includes a 8-foot grounded cord

Refrigeration

1/2 HP R134a lift-out high temperature condensing unit

Glycol Bath Capacity

• 14.80 U.S. gallons (56.0 l)

Maximum Distance to Taps

• 250 ft (53.4 m)

Circulating Pump

• 60 gph (227 lph)

Circulating Motor

• 1/3 HP (.25 kW)

Shipping Weight

• 125 lbs (56.7 kg)

Operating Weight

• 243 lbs (110 kg)

Shipping Cube

• 9.5 cu ft (.28 cu m)

Options

• Additional recirculating pump kit

• 4” Adjustable legs (up to 5-1/2”)

lc86 W

irinG

D

iaGram

BLACK

BLACK

BLACK

BLACK

BLACK

TERMINAL BLOCK

OPTIONAL

RECIRC MOTOR

LC86 ONLY

RECIRC MOTOR

COMPRESSOR

OPTIONAL

RECIRC SWITCH

LC86 ONLY

RECIRC SWITCH

GREEN

RECEPTICAL

CONDENSER FAN

TEMPERATURE CONTROL

GREEN

MAIN POWER

SUPPLY

115v/60hz

M

M

M

WHITE

WHITE

WHITE

WHITE

RUN START

RELAY START

COMMON

OVERLOAD

LC86