Rouble, Hooting – Glastender LC47 User Manual

Page 14

Advertising
background image

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780

800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com

11

9. t

rouble

s

hootinG

:

Complaints of warm beer...

• Check the temperature of walk-in beer cooler.

• Check the glycol bath temperature.

• Check that recirculating pump is operating.

Refrigeration Compressor Will Not Run...

• Check that the unit is getting electrical power.

• Check that cold control is working.

• Check that all wiring connections are secure.

Refrigeration Compressor Runs But Stops...

• Check for dirt build-up on condenser coil surface.

• Check that there is no obstruction of air flow into the cabinet.

• Ensure that enough voltage is supplied to the unit.

Refrigeration Compressor Runs But Not Cooling...

• Check for refrigerant leaks.

Noisy or Hot Recirculating Pump...

• Ensure that glycol bath is not frozen.

• Ensure that the glycol solution has been properly diluted.

• Check motor and pump coupling for wear.

Recirculation Pump Not Working...

• Ensure that pump and motor coupling has not worn free.

• Check power supply to the motor.

• Replace worn pump.

t

rouble

s

hootinG