12

t

yPical

i

nstallation

D

etail

8

7

6

5

PRIMARY REGULATOR

(STEP DOWN PRESSURE

TO BELOW 60 POUNDS)

4

3

2

1

KEG TAP

RED CO2

AIR LINE

TO KEG

CLEAR JUMPER LINES

CONNECT THE KEG

TO THE BEER PUMP

BEER LINES FROM LINE

SET ARE CONNECTED TO

THE BEER PUMPS

RESTRICTION LINES ON

TOWER ARE CONNECTED

TO THE BEER LINE SET

(DO NOT CHANGE LENGTH

WITHOUT CONSULTING

THE FACTORY)

TWO GLYCOL LINES GO

THRU CHASE, SO GLYCOL

CAN CIRCULATE BACK

TO THE LINE CHILLER.

(MUST INSULATE LINES

INSIDE WALK-IN T

O

PREVENT ICE BUILD-UP.)

INSULATED LINE CONTAINING

IN AND OUT GLYCOL LINES

MAIN CO2 LINE FRO

M

TANK MOUNT REGULATOR

RUNS TO WALK-IN COOLER

CO2 EXHAUST LINE

FROM BEER PUMPS

BEER PUMP

SECONDARY

REGULATORS CONTROL

CO2 PRESSURE TO KEGS

BEER LINES GOING

TO NEXT PANEL

AS NECESSARY

SIDE ELEVATION

OF BEER TOWER

ON BAR TOP

WALK-IN

COOLER

LINE

CHILLER

CHASEWAY

CO2

POWE

R

KEG

KEG

KEG

CO2 LINE GOING TO

NEXT BEER PUMP PANEL

AS NECESSARY

BEER PUMP REGULATOR

CONTROLS CO2 PRESSURE

TO BEER PUMPS