Lc65 s, Pecifications, Lc65 w – Glastender LC47 User Manual

Page 4: Iring, Iagram

Advertising
background image

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780

800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com

1

lc65 s

Pecifications

LC65

S

tanDarD

F

eatures

• Modular lift-out refrigeration system for easy

in-field service

• High capacity refrigeration and recirculation for

high volume and remote long distance installations

• CFC-free R134a refrigerant

• Light-weight, roto-molded glycol bath with drain

• Polyurethane foamed-in-place insulation
NOTE: Clearance of 12” required around unit for

maintenance and air flow.

Dimensions

• Height - 20.0” (49.5 cm)

• Width - 18.0” (45.7 cm)

• Depth - 25.75” (50.2 cm)

Electrical

• 115V, 1 phase, 60 Hz, 10.8 full load amps

• 230V, 1 phase, 50 Hz, 5.8 full load amps

• Dedicated 15 amp circuit is required

• Includes a 8-foot grounded cord

Refrigeration

1/3 HP R134a lift-out high temperature condensing unit

Glycol Bath Capacity

• 7.5 U.S. gallons (28.4 l)

Maximum Distance to Taps

• 125 ft (22.9 m)

Circulating Pump

• 60 gph (227 lph)

Circulating Motor

• 1/3 HP (.25 kW)

Shipping Weight

• 92 lbs (41.8 kg)

Operating Weight

• 152 lbs (69.1 kg)

Shipping Cube

• 9.5 cu ft (.28 cu m)

Options

• 4” Adjustable legs (up to 5-1/2”)

lc65 W

irinG

D

iaGram

BLACK

BLACK

BLACK

BLACK

BLACK

BLACK

BLACK

COMPRESSOR

GREEN

GREEN

RECIRC MOTOR

OPTIONAL

RECIRC MOTOR

GREEN

MAIN POWER

SUPPLY

230v/60hz

CONDENSER FAN

TERMINAL BLOCK

TEMPERATURE CONTROL

M

M

M

RED

RED

RED

RED

RED

RED

OVERLOAD

COMMON

RUN START

RELAY START

Advertising