Warning, Unit wiring – Comfort-Aire VMH 24 SD User Manual

Page 12

Advertising
background image

12

VMH 09/12/18/24 SD Inverter Mini-Split

Heat Controller

ELECTRICAL WIRING

AND SUPPLY VOLTAGE:

All electrical wiring must be done according to

local codes. Additionally installations in the USA,

must conform to the current National Electric Code

(NEC) and Installations in Canada must conform to

current Canadian Electric Code (CEC). Nameplate

data indicates the operating voltage, phase,

ampacity, maximum over current protection, and

minimum voltage.

The contractor is to provide an individual branch

circuit for over current protection for the unit as

required by code. Some codes may require a

disconnect between the indoor and outdoor unit.

Run power supply wiring through a weatherproof

disconnect box and conduit to the unit connection.

Disconnects are required to be within sight and

easy reach of the unit (usually within 3 feet).

Circuit breakers and disconnect switches should

be properly sized based on the required codes and

the unit’s nameplate requirements. (Fig.21)

Check the unit wiring diagram for the number of

conductors required. Ensure that the proper AWG

(gauge) and type of wired is used to comply with

code and the unit’s nameplate. Route neatly and

protect from sharp edges and damage.

Inadequate wiring and/or improper electrical

supply will likely result in failure of the compressor

and other electrical components and voids the

warranty.

Unit Wiring

WARNING

• Before performing any electrical work, ensure

all power is off. Electrical shock may occur.

• All outdoor unit’s capacitor’s to discharge

otherwise electrical shock hazard may occur.

• Ensure the unit is properly grounded.

Model

BTUH/H

9

12

18

24

POWER

(outdoor)

PHASE

1 Phase

1 Phase

1 Phase

1 Phase

VOLT

208/230V

208/230V

208/230V

208/230V

CIRCUIT BREAKER/FUSE (A)

15

15

20

25

MINIMUM CIRCUIT AMPACITY

9

9

13

15

NOTE: Subject to change. Always refer to unit’s nameplate.