Selecting installation place

Choose a location that places the outdoor unit as close to the indoor unit as

possible. The maximum unit separation and vertical lift (compressor above the

evaporator) must be taking into account. Do not exceed allowable refrigerant

line lengths.

Indoor unit

• Unit must be installed in a location that does not obstruct the flow of air

and ensures clearances are maintained. (Fig. 1)

• The site must support the weight of the unit.
• The site must be easily accessible for cleaning or replacement of the air

filter, maintenance and service.

• The indoor unit should be mounted as high up on the wall toward the

ceiling, leaving a minimum of 6” (150mm) of space between the ceiling

and the top of the indoor unit. (Fig. 1)

• Due to the possibility of electronic interference with other devices, it is

recommended that there should be at least to 3 ft (1 meter) between the

unit and other devices/appliances such as televisions or radios.

• The unit should be installed away from possible exposure to fire, smoke,

of flammable gases and be protected from direct sunlight (sunlight can

interfere with the signal between the unit and the remote controller.

Outdoor unit

• If installation location allows the unit to be exposed to strong winds (such

as coastal applications), ensure that the unit has a wind barrier. This will

assist with preventing strong gusts of wind from entering the unit’s cabinet

and interfering with the fan operation. (Fig. 3 and Fig. 4)

More than

10ft.(200cm)

Fig. 1

Fig. 2

Fig. 3

Fig. 4

Correct

Incorrect

wind gusts

Incorrect

Strong

wind

Strong

wind

Barrier

Correct

More than

12in.(30cm)

More than 24in.(60cm)

More than 12in.(30cm)

More than 6in.(15cm)

More than 6.5ft.(2.0cm)

More than 5in.(12cm)

More than 5in.(12cm)

Advertising