Electrical work, Outdoor unit power and communication cable wiring – Comfort-Aire VMH 24 SD User Manual

Page 14

Advertising
background image

14

VMH 09/12/18/24 SD Inverter Mini-Split

Heat Controller

Electrical Work

Outdoor unit power and

communication cable wiring

1. Remove the electrical control cover from the

outdoor unit (Fig. 24).

2. Connect power supply wires to the right side of

the outdoor unit’s terminal strip. (Fig. 25)

3. Connect the green/yellow ground from the power

supply wire to ground terminal. (Fig. 25)

4. Connect the communication cable from the

indoor unit to the outdoor unit’s terminal strip on

the left side. (Fig. 25)

5. Connect the ground wire of the communication

cable to the ground terminal. (Fig. 25)

6. To prevent water from entering in the unit, form a

loop in the cable (Fig. 26).

7. Insulate any unused conductors with electrical

tape, so that they do not touch any other

exposed electrical or metal parts.

Fig. 24

Fig. 26

Air inlet(side)

Air outlet

Screw

Cover

Loop the cable

Air inlet(rear)

Fig. 25

OR

To indoor unit

To power supply

To indoor unit

To power supply

Terminal block of outdoor unit

Conduit panel

Connecting cable

Power supply cord

To power supply

Cover control

Over 1 3/5in. (40mm)

Outdoor Unit

Advertising