Horizontal/Side Discharge Condensing Units

Heat Controller

OPERATING INSTRUCTIONS

Air conditioners are designed to provide comfort

cooling at outside temperatures above 65°F

(18°C) but less than 109°F (43°C). Operating the

air conditioner outside of this temperature range

may cause unit failure and will void the warranty.

If you have need for cooling at lower outdoor

temperatures a “low ambient cooling” can be field

installed. Contact your local contractor or call the

factory.

TO OPERATE:

NOTE: The thermostat operation may vary

by type and model used. Please consult the

operating manual that was provided with

the thermostat. The instructions below are

generalized for most standard thermostat

models.

1. Set the switch on your wall thermostat to the

‘cool’ position.

2. Set the desired temperature (between 63-86°F

or 17-30°C) you want to maintain by moving the

temperature setting on your thermostat. If the

room is warmer than the setting, the unit will

turn on and begin to blow cool air after a few

minutes. A warm, humid room or building may

take several hours of continuous operation to

cool to the thermostat set point the first time.

Once the set temperature is reached the unit

will cycle on and off.

3. Set the ‘Fan’ switch on the thermostat to ‘auto’

if you want the fan to run only when cooling

is needed or to ‘on’ if you want continuous

air circulation. The ‘on’ setting of the fan

generally provides better temperature control by

eliminating stagnant air.

NOTE: A properly installed and sized unit will

not cycle more than 10 times per hour. If you

notice more frequent starts call your service

contractor.

4. For energy conservation reasons, you may want

to set your thermostat at a higher temperature

when you are away. Do not raise the

temperature setting by more than 5 degrees.

Changing the temperature by more than 5

degrees or shutting the unit ‘off’ can actually

cost more than leaving the setting at a constant

temperature.

IMPORTANT

Wait at least 3 minutes after turning your air

conditioner off before trying to restart it. This

gives the unit the time needed to stabilize

before restarting. Failure to do so may cause

unit damage and failure.

MAINTENANCE:

Only simple periodic maintenance is required:

1. Change or clean the indoor unit air filer monthly

or more frequently if unusual conditions are

encountered. If you have a disposable type,

throw the old one away and install a fresh one

of the same size and type. If your unit has a

washable type then vacuum and wash with

soap and water. Flush thoroughly and dry

before re-installing.

2. Keep the coil in the outdoor unit clean.

Periodically flush the coil thoroughly with a

garden hose. Clean away all foreign materials

such as dust, leaves, grass clippings, papers,

etc.

IMPORTANT!

Alterations and replacement parts:

Altering the product or replacing parts

with non-authorized parts will void the

factory Warranty and may result in adverse

operational performance and/or a possible

hazardous safety condition to service

personnel and occupants. If you are in doubt

as to how to service this unit or where to find

factory replacement parts, call Heat Controller

at (517) 787-2100 for assistance.

WARNING

Turn the power off first! Serious injury or death

may result if water spray is directed at live

electrical connections or power sources.