GENERAL PRODUCT INFORMATION

UNPACKING AND INSPECTION:

The condensing unit is shipped completely

assembled and in it’s own package. All goods are

inspected at the factory and released to the freight

company in good condition. When received at the

site, a visual inspection of all packages should be

made immediately. Any evidence of rough handling

or apparent damage should be noted on the

delivery receipt and the material inspected in the

presence of the carrier’s representative. If damage

is found a claim should be immediately file with the

freight company.

COOLING OPERATION

TEMPERATURE LIMITS:

Heat Controller Condensing units are designed

to operate in cooling at outside temperatures

between 65°F (18°C) and 109°F (43°C). If

the condensing unit will be used to cool at

temperatures below 65°F (18°C), a low ambient

control must be field installed. Operation below

65°F (18°C) without low ambient control will void

the warranty.

INDOOR UNIT USE

AND SYSTEM EFFICIENCY:

Heat Controller condensing units are designed to

be compatible with most major brands of domestic

evaporator coils/air handlers. Imported ductless air

handlers maybe used but often do not include an

expansion device. A properly sized thermostatic

expansion valve is recommended. Consult AHRI’s

directory of certified products for indoor matches.

THERMOSTAT AND INDOOR

FAN TIME DELAY:

All indoor units should include a fan time delay.

This may be accomplished by using a digital wall

thermostat or installation of a 60 second fan time

delay designed to work with your specific furnace/

air handler.

Most brands of electronic thermostats include a

fan delay. Properly specified thermostats are the

responsibility of the installer. Proper temperature

control and unit operation depends on proper

thermostat selection and location. Refer to the

thermostat manufacturer’s installation instructions

for specified recommendations. Good practice is

to avoid outside walls, locations where the sun

may shine directly on the thermostat, and locations

where the air from supply registers or unit outlets

blow on the thermostat. Also avoid locations where

the thermostat could be jarred by a closing door or

high traffic area.

WARNING: An in-line filter drier is required

when the unit is installed. The filter drier is

not provided by the factory, therefore a locally

purchased filter drier must be used to remove

any particulates or moisture that may be

present in the system. Installations without an

in-line filter drier may void the warranty.