Festo Контроллер крайних положений SPC11 User Manual

Page 33

Advertising
background image

2. Parameters of the SPC11 for the DSMI−...

2−7

Festo P.BE−SPC11−DSMI−EN en 0910b

2.3

Parameters for the DSMI−...−... in horizontal operation

DSMI−...−... in horizontal operation

DSMI−25−...

DSMI−40−...

DSMI−63−...

0

−4

]

MPYE−5−M5−010B

0

−4

]

MPYE−5−1/8LF−010B

0

−4

]

MPYE−5−1/8LF−010B

Mass

moment

of

iner

tia

[kgm

2

*

10

Amplification

stage

(A)

Cushioning

stage

(C)

S

ystem

parameters

(S)

Time

[s]

Mass

moment

of

iner

tia

[kgm

2

*

10

Amplification

stage

(A)

Cushioning

stage

(C)

S

ystem

parameters

(S)

Time

[s]

Mas

moment

of

inetria

[kgm

2

*

10

Amplification

stage

(A)

Cushioning

stage

(C)

S

ystem

parameters

(S)

Time

[s]

20

On request

80

10

14

13

0,75

300

17

17

5

0,64

40

10

21

12

0,66

160

13

19

13

0,78

600

20

21

5

0,71

60

12

23

12

0,65

240

15

21

13

0,79

900

21

23

5

0,73

80

13

24

12

0,70

320

16

23

13

0,82

1200

23

25

5

0,76

100

14

26

12

0,74

400

17

24

13

0,83

1500

24

26

5

0,78

120

15

27

12

0,74

480

18

25

13

0,83

2100

26

28

5

0,82

140

15

28

12

0,79

560

19

25

13

0,81

2400

26

28

5

0,84

160

16

29

12

0,78

640

19

27

13

0,89

3300

27

30

5

0,90

180

16

29

12

0,77

720

20

26

13

0,82

4000

28

31

5

0,90

200

17

30

12

0,82

800

20

27

13

0,84

4400

29

32

5

0,91

220

17

31

12

0,87

880

21

27

13

0,86

4900

29

32

5

0,94

240

18

32

12

0,87

960

21

28

13

0,87

5500

29

33

5

0,98

260

18

31

12

0,82

1040

21

29

13

0,90

6000

30

34

5

1,00

280

18

33

12

0,90

1120

22

29

13

0,92

300

19

32

12

0,84

1200

22

29

13

0,90