Measuring system type mlo-pot-...-lwg ( 7 ) – Festo Контроллер крайних положений SPC11 User Manual

Page 25

Advertising
background image

1. Summary of components

1-11

Festo P.BE-SPC11-DNC-EN en 0012NH

Measuring system type MLO-POT-...-LWG (

7 )

S Use measuring system type MLO-POT-...-LWG (piston-rod

potentiometer) with the DNC-... .

The measuring system must be longer than the cylinder
stroke used. There must be an electric reserve. The fol-
lowing stroke lengths are possible, depending on the
measuring system length:

Measuring system length
[mm]

Max. usable stroke length
[mm]

100

90

150

140

225

215

300

290

360

350

450

440

600

590

750

735

S Mount the measuring system and the drive symmetrically,

so that the centre of the measuring system stroke co-
incides with the centre of the complete drive stroke (see
also System manual type P.BE-SPC11-SYS-...).

S For earthing, connect the earth strip to the flat plug of the

measuring system and to the earthing connection of the
SPC11 (see Fig. 1/1).

The earth strip in included with the measuring system.

Advertising