Table 10, Figure 12 and table 11 define the underside, Of the tp-124 xga/audio /data line receiver – Kramer Electronics TP-124 User Manual

Page 19

Advertising
background image

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Your TP-123/TP-124

16

Table 10: TP-124 XGA/Audio/Data Line Receiver (Topside) Features

#

Feature

Function

1

12V DC

+12V DC connector for powering the unit

2

A

UDI

O

OU

T S/PDIF RCA connector

Connects to the digital audio acceptor

3

ANALOG 3.5mm mini jack

Connects to the analog audio acceptor

4

RS-232 Terminal Block connector

Connects to the controlled unit

5

LINE IN RJ-45 connector

Connects to

1

the LINE OUT RJ-45 connector on the

TP-123 or

the

TP-104

2

6

XGA OUT 15-pin HD (F) connector

Connect to the XGA acceptor

7

LINK LED

Illuminates when receiving the correct input signal

8

LEVEL trimmer

Adjusts

4

the output signal level

9

EQ.

3

Adjusts

trimmer

4

10

the cable compensation equalization level

ON LED

Illuminates when receiving power

7.2.1 Your TP-124 XGA/Audio/Data Line Receiver (Underside)

Figure 12

and

Table 11

define the underside

5

of the TP-124 XGA/Audio

/Data Line Receiver:

Figure 12: TP-124 XGA/Audio/Data Line Receiver (Underside

1

)

Table 11: TP-124 XGA/Audio/Data Line Receiver (Underside) Features

#

Feature

Function

1

VS Switch

Slide the switch up

2

to set the V SYNC to positive polarity;

slide the switch down to set the V SYNC to negative polarity

2

HS Switch

Slide the switch up

6

1 Using a UTP cable with CAT 5 connectors at both ends (the PINOUT is defined in

to set the H SYNC to positive polarity;

slide the switch down to set the H SYNC to negative polarity

Table 12

and

Figure 14

)

2 The TP-104 does not accept the audio signals
3 Degradation and VGA/XGA signal loss can result from using long cables (due to stray capacitance), sometimes leading to a
total loss of sharpness in high-resolution signals
4 Use a screwdriver to carefully rotate the trimmer, adjusting the appropriate level
5 The underside is identical on the TP-122 and TP-124
6 By default, both switches are set down (for a negative V SYNC and H SYNC polarity)