Overview

5

5

3.2 About the Power Connect Feature

The Power Connect feature applies as long as the cable can carry power.

This feature is available when using STP cable and the distance does not

exceed 50m on standard CAT 5 cable. For longer distances, heavy gauge

cable should be used

1

For a CAT 5 cable exceeding a distance of 50m, separate power supplies

should be connected to the transmitter and to the receiver simultaneously.

.

For units which are connected via RJ-45 connectors,

make sure that the shield of the STP cable is connected to the metal casing

of the connectors on both ends of the cable. For units which are connected

via terminal block connectors, the shield of the STP cable must be

connected to a ground terminal on the units at both ends (use the ground

terminal of the power supply connection if necessary).

3.3 Recommendations for Achieving the Best Performance

To achieve the best performance:

Use only good quality connection cables

2

Avoid interference from neighboring electrical appliances that may

adversely influence signal quality and position your Kramer

product away from moisture, excessive sunlight and dust

to avoid interference,

deterioration in signal quality due to poor matching, and elevated

noise levels (often associated with low quality cables).

1 CAT 5 cable is still suitable for the video/audio transmission, but not for feeding the power at these distances
2 Available from Kramer Electronics on our Web site at

http://www.kramerelectronics.com

Advertising
This manual is related to the following products: