11.1 Default Communication Parameters

RS-232

Protocol

3000 (Default)

Legacy

Baud Rate:

115,200

9,600

Data Bits:

8

8

Stop Bits:

1

1

Parity:

None

None

Command Format:

ASCII

ASCII

Example (Set display mode to Picture in Picture):

#Y 0,110,1<CR>

>Y 0 110 1<CR>

Ethernet

To reset the IP settings to the factory reset values, power cycle the device while holding in the
Ethernet Reset button, located on the rear panel of the unit

IP Address:

192.168.1.39

Subnet mask:

255.255.000.000

Default gateway:

000.000.000.000

TCP Port #:

5000

UDP Port #:

50000

Maximum UDP Ports: 10

Maximum TCP Ports: 4

Full Factory Reset

Front panel buttons

Turn power off. Turn power on again while holding the RESET TO
XGA/720p front panel button. The LEDs blink. Full factory reset is
complete once the LEDs cease to blink and react normally

OSD

Factory Reset through the Misc menu item

Protocol 3000

Use “Factory” command or #Y 0,770,1<CR>

11.2 Input Resolutions

This section defines the input resolutions for each input

11.2.1

SDI Input Resolutions

SDI Input Resolution

NTSC

720_P60

1080_P24

1080_P50

PAL

1080_I50

1080_P25

1080_P60

720_P50

1080_I60

1080_P30