3 protocol table: mimicking osd – Kramer Electronics VP-774AMP User Manual

Page 71

Advertising
background image

66

VP-774AMP - The VP-774AMP RS-232 Communication Protocol

12.2.2

Using the Communication Protocol with Legacy Protocol

Set Command:

Type in: YControl_TypeFunctionParam[CR]

Reply: ZControl_TypeFunctionParam[CR][LF]

Get Command:

Type in: YControl_TypeFunction[CR]

Reply: ZControl_TypeFunctionParam[CR][LF]

When sending a command, a blank character may precede [CR] if desired

Example:

Example 1: set brightness value as 32

Send: Y041032[CR]

Reply: Z141032[CR][LF]

Example 2: get current output resolution. (4 = SVGA)

Send: Y1631[CR]

Reply: Z16314[CR][LF]

Character Symbols Definitions

Symbol

Meaning

Space

[CR]

Carriage Return, ASCII code 0x0D

[LF] or >

Line Feed, ASCII code 0x0A

12.2.3

Protocol Table: Mimicking OSD

You can associate a function number to its description and valid parameters

intuitively by navigating the OSD menu according to the following logic:

A function number is directly related to its location in the OSD menu.

For example, the third menu on the OSD is Process (3 in the hundreds). The

second menu item in Process is Film Mode (2 in the tens), therefore the function

number for it will be 320 (3

rd

item on the Main Window Control and the 2

nd

item in

the Process submenu (see also

Section

6.1

). When navigating in the OSD MENU

you will be able to see the Film Mode valid parameters. The following table defines

the protocol commands: