11
6.4 Dipswitch Settings
By default, all dipswitches are set to OFF.
Figure 4 illustrates the
VS-44HD dipswitches:
ON
1 2 3 4
SETUP
Figure 4: VS-44HD SETUP Dipswitches
6.4.1
Setting the Machine # Dipswitches
The Machine # determines the position of a
VS-44HD unit, specifying which
VS-44HD unit is being controlled when several VS-44HD units connect to a
PC or serial controller. Set the Machine # on a
VS-44HD unit via SETUP
DIPS 1, 2, 3 and 4, according to Table 3.
When using a standalone
VS-44HD unit, set the Machine # to 1. When
connecting more than one
VS-44HD unit, set the first machine (the Master)
that is closest to the PC, as Machine # 1 (dipswitches are set to OFF).
Table 3: Machine # Dipswitch Settings
Mach. #
DIP 1
DIP 2
DIP 3
DIP 4
1
OFF
OFF
OFF
OFF
2
OFF
OFF
OFF
ON
3
OFF
OFF
ON
OFF
4
OFF
OFF
ON
ON
5
OFF
ON
OFF
OFF
6
OFF
ON
OFF
ON
7
OFF
ON
ON
OFF
8
OFF
ON
ON
ON