Connecting Your VS-44HD

13

6.6 Controlling via the RS-485 Port

To cascade up to eight individual

VS-44HD units, via RS-485 (with control

via a Master Programmable Remote Control system such as the Kramer

RC-3000), as Figure 6 illustrates, do the following:

1. Connect the “A” (+) and “B” (-) PINS on the RS-485 terminal block port

of the

RC-3000 to the “A” (+) and “B” (-) PINS, respectively, on each of

the eight

VS-44HD units. (If using shielded twisted pair cable, the shield

is usually connected to the “G” (Ground) PIN of the first unit).

2. Set the first

VS-44HD unit as MACHINE # 1 and the following seven

VS-44HD units as MACHINE # 2 to MACHINE # 8, according to Table

3.

Figure 6: Controlling via RS-485 (for example, using an RC-3000)