Connecting the VS-88HC

15

6.3 Setting the Dipswitches

Figure 6 and Table 5 define the factory default dipswitches:

OFF

ON

1 2 3 4

Figure 6: Dipswitch Settings

Table 5: Dipswitch Settings

DIPS

Function

Description

1, 2, 3

Self Address

Set the MACHINE # (see section 6.3.1)

4

RS-485 Term

ON for RS-485 Line Termination with 120

OFF for no RS-485 Line Termination

6.3.1

Setting the Self Address #

To control a unit via RS-232 or RS-485, each unit has to be identified via its

unique Self Address #. Set the Self Address #

1

on a

VS-88HC unit via

dipswitches 1, 2 and 3, according to Table 6.

Table 6: Self Address # Dipswitch Settings

DIPSWITCH

Self

Address #

1

2

3

1

OFF

OFF

OFF

2

OFF

OFF

ON

3

OFF

ON

OFF

4

OFF

ON

ON

5

ON

OFF

OFF

6

ON

OFF

ON

7

ON

ON

OFF

8

ON

ON

ON

When connecting more than one

VS-88HC unit, set a different self address #

on each unit. You do not have to number the units in the sequence order in

which they connect to the PC, but it is essential that each unit is assigned a

unique machine number.

1 When using a single unit, set the unit to Self Address # 1