1-800-533-7533

Quest 110 Dual

Installation, Operation and Maintenance Instructions

10

www.QuestProtect.com

[email protected]

8. Service

WARNING! Servicing the Quest 110 Dual with its high pressure refrigerant system

and high voltage circuitry presents a health hazard which could result in death, serious
bodily injury, and/or property damage. Only qualified service people should service this
unit.
8.1 Technical Description

The Quest 110 Dual uses a refrigeration system similar to an air conditioner’s to remove heat and moisture
from incoming air, and add heat to the air that is discharged. Hot, high pressure refrigerant gas is routed from
the compressor to the condenser coil. The refrigerant is cooled and condensed by giving up its heat to the
air that is about to be discharged from the unit. The refrigerant liquid then passes through a filter/drier and
capillary tubing which cause the refrigerant pressure and temperature to drop. It next enters the evaporator
coil where it absorbs heat from the incoming air and evaporates.