4.2B Duct Outlet (fig. 2)

Dehumidification performance can be modified by adding an outlet duct to circulate air.

4.2C Remote Area, w/Outlets Ducted (fig. 3)

A more simplified remote installation method than above uses ducting between the Quest 110 Dual
discharge and the humid room; the Quest 110 Dual inlet draws air from the room in which it’s located. This
works well if there is an adequate air flow path between the two rooms; e.g. high door undercut or wall grill.
This eliminates the need to remote mount the humidity control.

4.3 Electrical Requirements

The Quest 110 Dual plugs into a common grounded outlet on a 110-120 VAC 15-Amp circuit. While
operating, it draws less than 7.2 amps @ 80°F, 60% RH and less than 6.8 amps @ 75°F, 50% RH. Use of
a ground fault circuit interrupter (GFCI) protected circuit is recommended. The unit should not be used in
areas prone to flooding.