Commissioning, operation – WIKA D-11-7 User Manual

Page 19

Advertising
background image

19

WIKA operating instructions pressure transmitter model D-1x-7

2478159.05 12/2011 GB/D/F/E

GB

Description of services

Software and hardware version

Via these services it is possible to read the firmware and hardware version.

Start and end of the measuring range

The byte "MBA (value)" or "MBE (value)" contains the amount of the corresponding value, where the

second most significant bit is taken as the algebraic sign (0=positive, 1=negative). This value is to be

calculated with the measuring range factor:

Date of manufacture

Service byte 1 contains the month of manufacture in the format MM (e.g. 08 for August) and service

byte 2 the year of manufacture in the format YY (e.g. 02 for 2002).

6. Commissioning, operation

Factor / unit (byte 3)

7 6 5 4 3 2 1 0

Exponent
00 00 00 0 ⇒ value x 10

0

00 00 01 1 ⇒ value x 10

1

00 00 10 2 ⇒ value x 10

2

00 00 11 3 ⇒ value x 10

3

Sign of the exponent
0 = positive

1 = negative

Measurement type
0 = relative pressure

1 = absolute pressure