7 external housing with version ip68, 7 external housing with version ip 68 – WIKA DPT-10 User Manual
Page 39
Advertising

5
.7 External housing with version IP 68
5
6
7
8
1
2
D
ispl
ay
I²C
4
5
1
2
3
Fig. 39: Electronics and connection compartment
1
Plug connector for service
2
Spring-loaded terminals for connection of the external indicating and
adjustment unit
3
Cable gland to the process component
4
Ground terminal for connection of the cable screen
5
Spring-loaded terminals for voltage supply
Electronics and connec-
tion compartment for
power supply
Differential pressure transmitter DPT10 - metal measuring diaphragm • Profibus PA
39
5 Connecting to power supply
37245
-