WIKA DPT-10 User Manual

Page 77

Advertising
background image

Measuring range

Thermal changes of the zero
signal and the output span relat-
ing to the adjusted span

-10 … +60 °C (+14 … +140 °F)

10 mbar, 30 mbar

±

(0.31 x TD + 0.06) %

100 mbar

±

(0.18 x TD + 0.02) %

500 mbar, 3 bar

±

(0.08 x TD + 0.05) %

16 bar

±

(0.1 x TD + 0.1) %

16 bar

±

(0.08 x TD + 0.05) %

-40 … +10 °C (-40 … +50 °F)

+

60 … +85 °C (+140 … +185 °F)

10 mbar, 30 mbar

±

(0.45 x TD + 0.1) %

100 mbar

±

(0.3 x TD + 0.15) %

500 mbar, 3 bar

±

(0.12 x TD + 0.1) %

16 bar

±

(0.15 x TD + 0.2) %

40 bar

±

(0.37 x TD + 0.1) %

Applies also to instruments with analogue 4 … 20 mA current output and refers to the set span.

Thermal change, current output

<

0.15 % at -40 … +80 °C (-40 … +176 °F)

Influence of the system pressure on the zero point and span

316L

, Alloy C276-, Alloy C276 gold-rhodium coated diaphragm

Measuring cell

10

mbar

30

mbar

100

mbar

500

mbar

Influence of the sys-
tem pressure to the
zero point

±

0.15 % of URL/

7 bar

±

0.35 % of URL/

70 bar

±

0.15 % of URL/

70 bar

±

0.075 % of URL/

70 bar

Influence of the sys-
tem pressure to the
span

±

0.035 % of URL/

7 bar

±

0.14 % of URL/

70 bar

±

0.14 % of URL/

70 bar

±

0.14 % of URL/

70 bar

Measuring cell

3

bar

16

bar

40

bar

Influence of the system
pressure to the zero point

±

0.075 % of URL/7 bar

±

0.075 % of URL/70 bar

±

0.075 % of URL/70 bar

Influence of the system
pressure to the span

±

0.14 % of URL/7 bar

±

0.14 % of URL/70 bar

±

0.14 % of URL/70 bar

Tantalum diaphragm

Measuring cell

10

mbar

30

mbar

100

mbar

500

mbar

Differential pressure transmitter DPT10 - metal measuring diaphragm • Profibus PA

77

11 Supplement

37245

-

EN

-100120