6.11.9

Unsolicited Response Control

Get Parameter Command Format:

Set Parameter Command Format:

Response Format:

Bits [31:0] are sticky and will not be reset by a Link Reset or a Codec Reset:

Unsolicited Response Format:

2:0

Read/Write

000b

VREF Enable (VREFE): This field selects one of
the possible states for the VREF signal(s). The
pin associated with this function is MICBIAS.
If the value written to this control does not corre-
spond to a supported value (‘000’b, ‘001’b,
‘010’b or ‘100’b), the VREFE bits must retain the
previous value.
‘000’b = Hi-Z
‘001’b = 0.5*VA
‘010’b = GND
‘100’b = 0.8*VA

Bits [31:28]

Bits [27:20]

Bits [19:8]

Bits [7:0]

CAd = X

Line In 1 Node ID=0Ch

Mic In 1 Node ID=0Dh

Verb ID = F08h

Payload = 00h

Bits [31:28]

Bits [27:20]

Bits [19:8]

Bits [7:0]

CAd = X

Line In 1 Node ID=0Ch

Mic In 1 Node ID=0Dh

Verb ID = 708h

Payload = xxh

Bits

Type

Default

Description

31:8

Read Only

000000h

Reserved

7

Read/Write

0b

Enable: Controls the actual generation of Unso-
licited Responses. 1 is enable; 0 is disable.

6

Read Only

0b

Reserved

5:0

Read/Write

000000b

Tag: Is a 6 bit value assigned and used by soft-
ware to determine what codec node generated
the unsolicited response. The value programmed
into the Tag field is returned in the top 6 bits
(31:26) of every Unsolicited Response gener-
ated by this node.

Bits [31:26]

Bits [25:0]

Tag

Response

Bits

Type

Default

Description

Advertising