31 limiter attack rate (address 29h), 1 limiter attack rate, 32 alc enable and attack rate (address 2ah) – Cirrus Logic CS42L52 User Manual

Page 67: 1 alcx enable, 2 alc attack rate, 1 alcx enable 6.32.2 alc attack rate, P 67

Advertising
background image

DS680F2

67

CS42L52

3/1/13

6.31

Limiter Attack Rate (Address 29h)

6.31.1

Limiter Attack Rate

Sets the rate at which the limiter applies digital attenuation from levels above the MAX[2:0] threshold
(

“Limiter Maximum Threshold” on page 65

).

Note:

The limiter attack rate is user-selectable but is also a function of the sampling frequency, Fs, and

the DIGSFT (

“Digital Soft Ramp” on page 53

) and DIGZC (

“Digital Zero Cross” on page 53

) setting unless

the respective disable bit (

“Limiter Soft Ramp Disable” on page 65

or

“Limiter Zero Cross Disable” on

page 66

) is enabled.

6.32

ALC Enable and Attack Rate (Address 2Ah)

6.32.1

ALCx Enable

Configures the automatic level controller.

Notes:

1.

When the ALC is enabled, the digital volume and PGA volume is automatically controlled and should
not be adjusted manually.

2.

The ALC should only be configured while the power down bit is enabled.

3.

The ALC is not available in passthrough mode.

6.32.2

ALC Attack Rate

Sets the rate at which the ALC applies analog and/or digital attenuation from levels above the AMAX[2:0]
threshold (

“ALC Maximum Threshold” on page 68

).

Note:

The ALC attack rate is user-selectable but is also a function of the sampling frequency, Fs, and

the ANLGSFTx (

“Ch. x Analog Soft Ramp” on page 49

) and ANLGZCx (

“Ch. x Analog Zero Cross” on

page 49

) setting unless the respective disable bit (

“ALCx Soft Ramp Disable” on page 55

or

“ALCx Zero

Cross Disable” on page 56

) is enabled.

7

6

5

4

3

2

1

0

Reserved

Reserved

LIMARATE5

LIMARATE4

LIMARATE3

LIMARATE2

LIMARATE1

LIMARATE0

LIMARATE[5:0]

Attack Time

00 0000

Fastest Attack

···

···

11 1111

Slowest Attack

Application:

“Limiter” on page 30

7

6

5

4

3

2

1

0

ALCB

ALCA

ALCARATE5

AALCRATE4

ALCARATE3

ALCARATE2

ALCARATE1

ALCARATE0

ALC

ALC Status

0

Disabled

1

Enabled

Application:

“Automatic Level Control (ALC)” on page 26

LIMARATE[5:0]

Attack Time

00 0000

Fastest Attack

···

···

11 1111

Slowest Attack

Application:

“Automatic Level Control (ALC)” on page 26

Advertising