6.5.2

Control Port Enable (Bit 5)

Function:

This bit defaults to 0, allowing the device to power-up in Stand-Alone mode. The Control port mode
can be accessed by setting this bit to 1. This will allow the operation of the device to be controlled by
the registers and the pin definitions will conform to Control Port Mode. To accomplish a clean power-
up, the user should write 30h to register 5 within 10 ms following the release of Reset.

6.5.3

Power Down (Bit 4)

Function:

The device will enter a low-power state whenever this function is activated (set to 1). The power-down
bit defaults to ‘enabled’ (1) on power-up and must be disabled before normal operation will begin. The
contents of the control registers are retained when the device is in power-down.

6.5.4

AMUTEC = BMUTEC (Bit 3)

Function:

When this function is enabled, the individual controls for AMUTEC and BMUTEC are internally con-
nected through a AND gate prior to the output pins. Therefore, the external AMUTEC and BMUTEC
pins will go active only when the requirements for both AMUTEC and BMUTEC are valid.

6.5.5

Freeze (Bit 2)

Function:

This function allows modifications to the control port registers without the changes taking effect until
Freeze is disabled. To make multiple changes in the Control port registers take effect simultaneously,
set the Freeze Bit, make all register changes, then Disable the Freeze bit.

6.5.6

Master Clock Divide (Bit 1)

Function:

This function allows the user to select an internal divide by 2 of the Master Clock. This selection is
required to access the higher Master Clock rates as shown in Tables 2 through 4 on page 10.

6.6

Mode Control 3 - Address 06h

6.6.1

Interpolation Filter Select (Bit 4)

Function:

This Function allows the user to select whether the Interpolation Filter has a fast (set to 0 - default) or
slow (set to 1) roll off. The - 3dB corner is approximately the same for both filters, but the slope of
the roll of is greater for the ‘fast’ roll off filter.

B7

B6

B5

B4

B3

B2

B1

B0

Reserved

Reserved

Reserved

FILT_SEL

RMP_UP

RMP_DN

Reserved

Reserved