RECOMMENDED OPERATING SPECIFICATIONS

(AGND = 0V; all voltages with respect

to AGND.)

ABSOLUTE MAXIMUM RATINGS

(AGND = 0 V; all voltages with respect to ground.)

WARNING: Operation at or beyond these limits may result in permanent damage to the device. Normal operation is

not guaranteed at these extremes.

Parameters

Symbol Min

Typ

Max

Units

DC Power Supply

VA
VL

4.75

1.8

5.0

-

5.25

VA

V
V

Parameters

Symbol

Min

Max

Units

DC Power Supply

VA
VL

-0.3
-0.3

6.0

VA

V
V

Input Current, Any Pin Except Supplies

I

in

-

±10

mA

Digital Input Voltage

V

IND

-0.3

VL+0.4

V

Ambient Operating Temperature (power applied)

T

A

-55

125

°C

Storage Temperature

T

stg

-65

150

°C