Cs4392, Dc electrical characteristics, Digital input characteristics & specifications – Cirrus Logic CS4392 User Manual

Page 36: Thermal characteristics and specifications

Advertising
background image

CS4392

36

DS459PP3

DC ELECTRICAL CHARACTERISTICS

(AGND = 0V; all voltages with respect to AGND.)

Notes: 10. Normal operation is defined as RST = HI with a 997 Hz, 0dBFS input sampled at F

s

= 48kHz, and open

outputs, unless otherwise stated.

11. Power-Down Mode is defined as RST = LO with all clocks and data lines held static.
12. Valid with the recommended capacitor values on FILT+ and VQ as shown in Figures 1 and 2.

DIGITAL INPUT CHARACTERISTICS & SPECIFICATIONS

(AGND = 0V; all voltages

with respect to AGND.)

THERMAL CHARACTERISTICS AND SPECIFICATIONS

Parameter

Symbol

Min

Typ

Max

Units

Normal Operation

(Note 10)

Power Supply Current

All Supplies=5.0V

I

A

+ I

L

-

26

30

mA

Power Dissipation

-

130

150

mW

Power-Down Mode

(Note 11)

Power Supply Current

All Supplies=5.0V

I

A

+ I

L

-

300

-

µA

Power Dissipation

-

1.5

-

mW

All Modes of Operation
Power Supply Rejection Ratio

(Note 12)

(1 kHz)

(60 Hz)

PSRR

-
-

60
40

-
-

dB
dB

Common Mode Voltage

Output Impedance
Maximum allowable DC current source/sink

CMOUT

-
-
-

0.48•VA

250

0.001

-
-
-

V

k

mA

Filt+ Nominal Voltage

Output Impedance
Maximum allowable DC current source/sink

-
-
-

VA

250

0.001

-
-
-

V

k

mA

MUTEC Low-Level Output Voltage

-

0

-

V

MUTEC High-Level Output Voltage

-

VA

-

V

Maximum MUTEC Drive Current

-

3

-

mA

Parameters

Symbol Min Typ

Max

Units

Input Leakage Current

I

in

-

-

±10

µA

Input Capacitance

-

8

-

pF

High-Level Input Voltage

V

IH

70%

-

-

VL

Low-Level Input Voltage

V

IL

-

20%

VL

Parameters

Symbol Min Typ

Max

Units

Package Thermal Resistance

CS4392-KS

CS4392-KZ/KZZ

θ

JA

θ

JA

-
-

68
72

-
-

°C/Watt
°C/Watt

Ambient Operating Temperature

(Power Applied)

T

A

-10

-

+70

°C

Advertising