3 load performance with sentec, 1 active energy load performance, An365 – Cirrus Logic AN365 User Manual
Page 11
Advertising

AN365
AN365REV1
11
4.3 Load Performance with Sentec
4.3.1 Active Energy Load Performance
Power Factor
Load Current (A)
Current Dynamic Range (x:1)
Error
PF = 1
120
1
0.02%
60
2
0.02%
12
10
0.02%
1.2
100
0.02%
0.24
500
0.02%
0.12
1000
0.03%
0.06
2000
0.03%
0.036
3333
0.06%
0.03
4000
-0.07%
Lagging PF = 0.5
120
1
0.02%
60
2
0.02%
12
10
0.01%
1.2
100
0.01%
0.24
500
0.03%
0.12
1000
0.02%
0.06
2000
0.01%
Leading PF = 0.5
120
1
0.02%
60
2
0.03%
12
10
0.01%
1.2
100
0.00%
0.24
500
0.01%
0.12
1000
-0.01%
0.06
2000
0.00%
Table 9. Active Energy Load Performance
-0.30
-0.20
-0.10
0.00
0.10
0.20
0.30
0.01
0.1
1
10
100
P
e
rcentage E
rror
Load Current (A)
Leading PF = 0.5
Lagging PF = 0.5
PF = 1
Figure 10. Active Energy Load Performance