4.2 Load Performance with Rogowski Coil TR9L

4.2.1 Active Energy Load Performance

Power Factor

Load Current (A)

Current Dynamic Range (x:1)

Error

PF = 1

120

1

0.01%

60

2

0.04%

12

10

0.06%

1.2

100

0.02%

0.24

500

0.01%

0.12

1000

0.00%

0.06

2000

-0.02%

0.036

3333

0.00%

0.03

4000

0.02%

Lagging PF = 0.5

120

1

0.05%

60

2

0.04%

12

10

0.03%

1.2

100

-0.06%

0.24

500

0.05%

0.12

1000

0.01%

0.06

2000

-0.01%

Leading PF = 0.5

120

1

0.01%

60

2

-0.02%

12

10

-0.03%

1.2

100

-0.03%

0.06

2000

-0.09%

Table 6. Active Energy Load Performance

-0.3

-0.2

-0.1

0

0.1

0.2

0.3

0.01

0.1

1

10

100

P

e

rcentag

e

E

rror (%)

Load Current (A)

PF = 1

Lagging PF = 0.5

Leading PF = 0.5

Figure 7. Active Energy Load Performance