2 load performance with rogowski coil tr9l, 1 active energy load performance, An365 – Cirrus Logic AN365 User Manual
Page 8
Advertising

AN365
8
AN365REV1
4.2 Load Performance with Rogowski Coil TR9L
4.2.1 Active Energy Load Performance
Power Factor
Load Current (A)
Current Dynamic Range (x:1)
Error
PF = 1
120
1
0.01%
60
2
0.04%
12
10
0.06%
1.2
100
0.02%
0.24
500
0.01%
0.12
1000
0.00%
0.06
2000
-0.02%
0.036
3333
0.00%
0.03
4000
0.02%
Lagging PF = 0.5
120
1
0.05%
60
2
0.04%
12
10
0.03%
1.2
100
-0.06%
0.24
500
0.05%
0.12
1000
0.01%
0.06
2000
-0.01%
Leading PF = 0.5
120
1
0.01%
60
2
-0.02%
12
10
-0.03%
1.2
100
-0.03%
0.06
2000
-0.09%
Table 6. Active Energy Load Performance
-0.3
-0.2
-0.1
0
0.1
0.2
0.3
0.01
0.1
1
10
100
P
e
rcentag
e
E
rror (%)
Load Current (A)
PF = 1
Lagging PF = 0.5
Leading PF = 0.5
Figure 7. Active Energy Load Performance
Advertising