2 reactive energy load performance, An365 – Cirrus Logic AN365 User Manual

Page 9

Advertising
background image

AN365

AN365REV1

9

4.2.2 Reactive Energy Load Performance

Power Factor

Load Current (A)

Current Dynamic Range (x:1)

Error

sin

= 1

120

1

-0.01%

12

10

-0.03%

1.2

100

-0.04%

0.24

500

-0.05%

0.12

1000

-0.04%

0.06

2000

0.06%

0.036

3333

0.02%

0.03

4000

0.01%

Lagging sin

= 0.5

120

1

0.17%

12

10

0.24%

1.2

100

0.14%

0.24

500

0.10%

0.12

1000

0.07%

0.06

2000

0.07%

Leading sin

= 0.5

120

1

-0.20%

12

10

0.24%

1.2

100

-0.22%

0.24

500

-0.22%

0.12

1000

-0.22%

0.06

2000

-0.21%

Table 7. Reactive Energy Load Performance

-1

-0.5

0

0.5

1

0.01

0.1

1

10

100

Pe

rc

e

n

ta

ge

Er

ror (

%

)

Load Current (A)

sin

ࢥ = 1

Lagging sin

ࢥ = 0.5

Leading sin

ࢥ = 0.5

Figure 8. Reactive Energy Load Performance