1 load performance with rogowski coil pa3202nl, 1 active energy load performance, An365 – Cirrus Logic AN365 User Manual
Page 5
Advertising

AN365
AN365REV1
5
4.1 Load Performance with Rogowski Coil PA3202NL
4.1.1 Active Energy Load Performance
Power Factor
Load Current (A)
Current Dynamic Range (x:1)
Error
PF = 1
80
1
0.04%
8
10
0.04%
0.8
100
0.04%
0.16
500
0.04%
0.08
1000
0.07%
0.04
2000
0.05%
0.03
3333
0.06%
0.02
4000
0.02%
Lagging PF = 0.5
80
1
0.05%
8
10
0.05%
0.8
100
0.04%
0.16
500
0.06%
0.08
1000
0.05%
0.04
2000
0.06%
Leading PF = 0.5
80
1
0.04%
8
10
0.04%
0.8
100
0.05%
0.16
500
0.04%
0.08
1000
0.05%
0.04
2000
0.07%
Table 3. Active Energy Load Performance
-0.3
-0.2
-0.1
0
0.1
0.2
0.3
0.01
0.1
1
10
100
Pe
rc
e
n
ta
ge
Er
ror (
%
)
Load Current (A)
PF = 1
Lagging PF = 0.5
Leading PF = 0.5
Figure 4. Active Energy Load Performance