3 irms load performance, Summary, An365 – Cirrus Logic AN365 User Manual

Page 13

Advertising
background image

AN365

AN365REV1

13

4.3.3 I

RMS

Load Performance

Figure 12. I

RMS

Load Performance

5. Summary

The CS5480 energy measurement IC supports Rogowski coils using digital integrators. With the exception of two
single-pole RC filters, no other external components are required. With on-chip digital calibration and compensation
algorithms, the CS5480 can achieve 0.1% energy measurement accuracy over 4000:1 dynamic range.

Load Current (A)

Current Dynamic

Range (x:1)

I

RMS

Register Value

(10-Second Average)

I

RMS

Error

120

1

0.599985965

0.00%

60

2

0.300011613

0.00%

12

10

0.06000053

0.00%

1.2

100

0.006000024

0.00%

0.24

500

0.001199722

-0.02%

0.12

1000

0.000600541

0.09%

Table 11. I

RMS

Load Performance

-0.3

-0.2

-0.1

0

0.1

0.2

0.3

0.1

1

10

100

Pe

rc

e

n

ta

ge

Er

ror (

%

)

Load Current (A)

Advertising