3 irms load performance, Summary, An365 – Cirrus Logic AN365 User Manual
Page 13
Advertising

AN365
AN365REV1
13
4.3.3 I
RMS
Load Performance
Figure 12. I
RMS
Load Performance
5. Summary
The CS5480 energy measurement IC supports Rogowski coils using digital integrators. With the exception of two
single-pole RC filters, no other external components are required. With on-chip digital calibration and compensation
algorithms, the CS5480 can achieve 0.1% energy measurement accuracy over 4000:1 dynamic range.
Load Current (A)
Current Dynamic
Range (x:1)
I
RMS
Register Value
(10-Second Average)
I
RMS
Error
120
1
0.599985965
0.00%
60
2
0.300011613
0.00%
12
10
0.06000053
0.00%
1.2
100
0.006000024
0.00%
0.24
500
0.001199722
-0.02%
0.12
1000
0.000600541
0.09%
Table 11. I
RMS
Load Performance