START UP / PUMP CALIBRATION

Mechanical Adjustment:

Note: Your CL unit comes factory set at 50% flow.

By adjusting the angle of the high pressure pump head

(pump head on right side of drive) using the adjustment

knob, piston displacement can be increased and

decreased, which in turn will vary flow rate.

Diagram 6

shows the minimum (0%), maximum (100%), and

factory set (50%) pump head positions.


Electronic Adjustment:

The C100A Variable Speed

Controller varies pump speed and has both manual and

electronic control modes.

For manual speed adjustment, set the C100A ON/OFF

switch to the “ON” position and set the rotary dial to 6.

Turn On and measure discharge flow. Adjust flow as

necessary.

For speed control from an external 4-20mA source, set

the ON/OFF switch to the “AUTO” position.

Diagram 6

FLUIDIC CONNECTIONS

1.

Connect the supply tubing from the hypochlorite

supply vessel to the 1/4” NPT female CL Supply
Inlet

fitting of the Chloritrol CL. Supply tubing

should be 1/4” to 3/8” ID semi-rigid translucent

tubing, LDPE (low density polyethylene) or

equivalent.

Refer to Fluidic Overview Diagram 5.

Important Note: Do not use any fittings having

Buna-N seal elements. Only Viton® should
be used.





2.

Connect the Return tubing from the 1/4” NPT

female CL Return back to the supply vessel.

Return tubing should be 1/4” to 3/8” ID semi-

rigid tubing, LDPE (low density polyethylene)

or equivalent.

Refer to Fluidic Overview

Diagram 5.


3.

Connect 1/4” OD tubing (semi-rigid

suggested), from the CL Dispense (1/4” NPT

female) to the point of chlorination, typically

the groundwater well or water main.

Sodium Hypochlorite

Chlorine Analyzer

or other 4-20 mA source

IN-CL-14

3/11/14 HW

Diagram 5

Fluidic Overview