C100a variable speed dc controller – FMI CL1 User Manual

Page 6

Advertising
background image








C100A CONTROLLER

Supply Voltage: 120 VAC 50/60 Hz, 0.5 Amp

Fuses: The C100A is provided with a fuse in the AC line (P1-11).

This fuse is sized to open in the event of a shorted armature or if

an armature line is shorted to ground.

Speed Control Input via 3 position ON/OFF switch:

1) “ON” position = Manual (Rotary Dial)

2) “AUTO” position = Electronic (4-20 mA) source

Dimensions: 7.0” H x 5.53 W

Enclosure: NEMA 4/12

C100A Variable Speed DC Controller

GENERAL

The FMI C100A Variable Speed DC Controller is designed to

operate with FMI Variable Speed CL and CTS Drives.

The C100A features both manual speed adjustment (“ON”

position) using a front panel mounted rotary control, as well as

electronic speed control (“AUTO” position) via a 4-20mA signal

from an external source (sensor, analyzer, process controller..

etc).

The C100A incorporates transient voltage protection with

adjustable current limit and AC fuse for protection. It features

adjustable minimum and maximum speeds along with

adjustable acceleration and IR compensation.

The electronics are housed in a gasketed NEMA 4/12 enclosure

suitable for wall mounting.

IMPORTANT: The C100A Control Unit is factory calibrated for

optimum performance. Adjusting internal pots may void

warranty.

Diagram 7

Mounting Diagram

MOUNTING PROCEDURE

The C100A has two (2) mounting slots located on flanges

on each side of the chassis as shown in

Diagram 7 (right)

suitable for wall or vertical panel mounting. It is

recommended that all four (4) mounting slots be utilized for

maximum stability.

There are two 1/2” NPT female conduit fittings located at

the bottom of the C100A enclosure for connecting electrical

conduit. Allow adequate access to the area surrounding

these fittings for connecting electrical conduit.

1/2” NPTF conduit fittings

IN-CL-14

3/11/14 HW

Page 6 of 10