Using revolabs microphones and microphone adapters – Revolabs Solo Executive Operation Manual User Manual

Page 15

Advertising
background image

- 12 -

Using the Rear Panel BUS Connector for Multiple Systems

If more than one Revolabs Solo™ Executive Base Station is used in an area,
each unit needs to be interconnected with a synchronization (BUS) cable using
a standard 3.5mm mini-Phoenix connector, and the LOCAL / REMOTE switch
needs to be adjusted on one or more of the units.

The three terminals of the BUS connector correspond to positive +, negative -,
and ground

(seen left to right with the connector installed). See

Understanding Connectors above for further details.

Set one Base Station as the REMOTE by sliding the switch next to the BUS
port to the right. The other unit must remain set to LOCAL (switch to the left -
default position). In this configuration, the LOCAL unit manages the entire
system, distributing microphone transmission across available channels to
maintain frequency integrity, and coordinating system muting.

Position 1 (left side – LOCAL - default): This designates the Base Station as the
master control unit. See Appendix B for additional instructions.

Position 2 (right side - REMOTE): Slide the switch on the second system to the
REMOTE position so it is controlled by the LOCAL unit.

Note:

The Power Switch must be cycled (off/on) for the status change to take

effect.

Warning: The switch must be in the LOCAL position for a single Base Station
system. Microphones will not function if the switch is in the REMOTE position.

In EU frequency systems, additional Base Stations can be connected by
paralleling conductors through the mini-Phoenix terminals (e.g., there would be
two conductors in each of the three terminals of the second Base Station in a
three Base Station system.) Additional systems would also be set to the
REMOTE position.

The maximum number of microphone channels within a 100’ (30m) radius in
North America is 16 channels. The maximum number of channels within a
100’ (30m) radius for an EU frequency system is 24 channels.

Note: An Executive Single Channel can not be used in the same installation
with an Executive multichannel system because there is no way to synchronize
the units to prevent mutual signal interference.

Using Revolabs Microphones and Microphone Adapters

Use any of three microphones with your Revolabs Solo™ Executive system:

• Revolabs Solo™ Wearable Wireless Microphone.

Advertising