3 sanitizing – Vollrath Mix60-Water Cooled User Manual

Page 18

Advertising
background image

English

Mixer

18

-

Each component mentioned in “Complete washing and disassembling of the parts” must be washed using a suitable
brush in a solution consisting of 2 oz of detergent suitable for use with food preparation equipment in 2 gallons of hot
water (104°F).

-

Rinse each part using water at room temperature.

3 Sanitizing

-

Prepare a solution consisting of 2 oz of Spartan Chemical SANI- T- 10 disinfectant in 2 gallons of water at room
temperature. Immerse all the components mentioned in “accurate washing and disassembling of the parts” in this
solution for 5 minutes.

-

Remove the components from the solution; lubricate the seals and the inner surfaces of the tap joint using lubricant
suitable for use with food preparation equipment. Re- assemble all the sanitized parts.

-

For Mix60 pour a solution consisting of 4 oz of Spartan Chemical SANI- T- 10 disinfectant in 4 gallons of water at room
temperature into the tank. Clean all the tank surfaces and the lid, using disposable sterile material or suitable brush.
Press the stir button and allow the machine to run for 5 minutes before emptying the tank.

-

For Mix120 pour a solution consisting of 8 oz of Spartan Chemical SANI- T- 10 disinfectant in 8 gallons of water at
room temperature into the tank. Clean all the tank surfaces and the lid, using disposable sterile material or suitable
brush. Press the stir button [K6] and allow the machine to run for 5 minutes before emptying the tank.

-

Rotate the drip tray collector to one side, position a container under the tap and open it to empty the tank.

-

The machine should be rinsed first with a sanitizing solution and then with potable water, ensuring that the correct
hygiene procedures are observed, in accordance with state and local health codes.

-

Each time the machine is cleaned, it must be sanitized, using sterile gloves. Sanitization must be carried out on a
regular basis in accordance with local hygiene regulations.

8

M

AINTENANCE

The device requires very limited maintenance. Periodically, we suggest to:

-

check the condition of the parts of the device. During disassembly is an ideal opportunity to inspect parts (ref. Par.
8. 1);

-

check that electric power cable, pipe fittings (rubber hoses) and water pipes are not damaged;

-

Test all safety devices (ref. Par. 8.2).

Examine and clean external panels and surrounding area. Dust, paper fragments or other small objects may block the
ventilation ducts (specially if equipped with air condenser).

Internal parts must only be inspected by a qualified Service Technician (ref. Par. 8. 3)

Advertising