10 m, 3 annual maintenance – Vollrath Mix60-Water Cooled User Manual

Page 20

Advertising
background image

English

Mixer

20

8.3

Annual maintenance

Periodically (based on the environmental conditions in which the device operates) or at least once every year, make sure
to have a general checkup.

THE CHECK-UP MUST BE MADE BY A QUALIFIED SERVICE TECHNICIAN WITH ADEQUATE TOOLS.
THE MAINTENANCE OPERATIONS CAN BE DANGEROUS IF CARRIED OUT BY NON-PROFESSIONALS,
THEREFORE, FOR YOUR OWN SAFETY, THE USER MUST NEVER CARRY THEM OUT.

9

P

ERIODS OF INACTIVITY

If long periods of inactivity are foreseen, proceed as follows:

-

ensure that the Main circuit breaker is turned off;

-

remove the electrical plug from the outlet.

-

Completely clean the device (see Chapter 7);

-

close the water faucet and relieve pressure from inside the supply hose by unscrewing one of the pipe fittings.
Remove both supply and drain hoses and let all water drain. Before using the hoses again, following a long period of
inactivity, check for any damages or cracks and replace, pipe fittings’ gaskets if necessary.

-

if the device will be stored in a different place, group all the documentation, together with this manual, and enclose it
in the device (for example inside the tank).

Before storing the device in rooms with a temperature lower than 0°C (32°F) it is IMPORTANT to get rid
of the water in the condenser (with WATER condensed units) and in the inlet, outlet and washing hoses.
Call a qualified Refrigeration Service Technician.

10 M

ALFUNCTIONS

CONTACT A QUALIFIED SERVICE TECHNICIAN IMMEDIATELY IF A MALFUNCTION OTHER THAN FROM
THOSE DESCRIBED BELOW IS DISCOVERED.

Note:

the following malfunctions do not refer to problems realized during the installation phase, but ONLY to correctly
installed - and already functioning - devices.

THE DEVICE DOES NOT SEEM TO BE WORKING AT ALL.

With the Main Breaker on, the ON/OFF indicator [Z1] DOES NOT TURN ON.

Cause:

The electrical plug is not plugged in correctly.

The receptical is defective. A qualified technician should replace it.

No power to the recptical. Check that the Main Switches, and circuit protection (breakers)
are closed. If they are open verify that no one is servicing the equipment before closing the
circuit.

The supply cable is defective. Turn circuit breaker off, then disconnect the plug and call a
Service Technician.

DO NOT TOUCH THE DAMAGED ELECTRICAL CABLES BEFORE TURNING OFF THE
CIRCUIT BREAKER.

With the Main Breaker on, the ON/OFF indicator [Z1] TURNS ON, but the display shows 3 small squares
and the device does not work.

Cause: The impeller's cover is not properly closed;

The impeller's cover. Call a Service Technician.