Replacing the MECHANISM ASSEMBLY

Warning

Dangerous Voltage

[1] Disconnect the main power.

[2] Do the replacement procedure for the LOWER

HOUSING ASSEMBLY.

[3] Cut and remove the necessary WIRE TIES.

[4] Disconnect the 2 wires from the CYCLE

SOLENOID on the SMALL CIRCUIT BOARD.

[5] Pull the SMALL CIRCUIT BOARD up.

[6] Disconnect all wires connected to the

MECHANISM ASSEMBLY:

• 1 yellow wire from CYCLE SWITCH

• 1 orange wire from WIRE NUT

• 1 green wire from POWER CORD

• 2 green ground wires from the lower

MECHANISM ASSEMBLY

[7] Remove the FOCUS KNOB from the FRONT

PANEL.

[8] Remove the 3

Torx SCREWS from the LENS

MOUNT ASSEMBLY.

[9] Lift and move the LENS MOUNT ASSEMBLY up.

[10] Do the replacement procedure for the MOTOR.

[11] Remove the 3

Torx SCREWS from the

MECHANISM ASSEMBLY.

[12] Loosen the SCREW on the STABILIZER WALL

approximately half way.

Caution

There might be a bind between the SELECT LEVER
and the SELECT BUTTON when removing the
MECHANISM ASSEMBLY. Do not use force; this
might cause damage to the SELECT BUTTON.

[13] Remove the MECHANISM ASSEMBLY.

Installing the MECHANISM ASSEMBLY

Important

To insert the SELECT BUTTON into the hole in the SELECT LEVER when installing the MECHANISM ASSEMBLY,
hold the SELECT BUTTON completely down.

[1] Do the removal procedure for the MECHANISM ASSEMBLY in reverse order.

A091_4047CA

ASSEMBLY

MECHANISM

FOCUS KNOB

SCREW

MOUNT

LENS

SCREW (3)

A091_4047CCA