Specifications

SM5440-1 – 18NOV97

41

REMOTE INLET

Automatic Timer

Operates between the following times:

• Fast = 3 1 second

• Slow = 22 6 seconds

Elevation

14 maximum front elevation assembly.

Auto Focus System

• After the initial focus adjustment, the auto-

focus system will adjust for the difference in
the slide position from slide to slide. This
focus adjustment will occur within 1 second
after the slide is inserted into the GATE.

• The focus adjustment variation should not

change from the focus and reverse
specifications by more than 3 times the
focus and reverse specifications.

Reliability

The projector can operate for 2000 hours or
2,000,000 cycles. The projector has a MTBF
(mean time between failures) of 7500 operation
hours.

Maintenance

Preventive maintenance by a qualified service
person is recommended every 1500 hours of
operation, or after 1 year.

Warranty

See the owner’s manual.

7-PIN REMOTE CONTROL
(See illustration on next page.)

• PIN 1 - Black, REMOTE FOCUS

• PIN 2 - Green, FORWARD TRAY CYCLE

• PIN 3 - Orange, REVERSE TRAY CYCLE

• PIN 4 - Brown, RACK SOLENOID

• PIN 5 - Yellow, COMMON

• PIN 6 - Brown, LAMP CONTROL

• PIN 7 - White, LAMP CONTROL

Item

Desription

1

2

3

4

5

6

7

A100_0023AA

Y

W

N

O

G

N

K

7-PIN PLUG

A100_0023ACA

24 V AC

24 V AC

24 V AC

0 V AC

Common

Unloaded

82 V AC

Advertising