14

18NOV97 – SM5440-1

Replacing the AUTO-FOCUS BRACKET ASSEMBLY

Warning

Dangerous Voltage

[1] Disconnect the main power.

[2] Do the replacement procedure for the LOWER HOUSING ASSEMBLY.

[3] Cut and remove the necessary WIRE TIES.

[4] Disconnect the 2 wires from the CYCLE SOLENOID on the SMALL CIRCUIT BOARD.

[5] Pull the SMALL CIRCUIT BOARD up.

[6] Do the replacement procedure for the MECHANISM ASSEMBLY.

[7] Remove the

Torx SCREW from the WORM PULLEY.

[8] Remove the WORM PULLEY.

[9] Remove the 2

Hex SCREWS from the CYCLE SOLENOID.

[10] Remove the CYCLE SOLENOID.

[11] Remove the

Phillips SCREW from the AUTO-FOCUS BRACKET ASSEMBLY.

[12] Pull and remove the AUTO-FOCUS BRACKET ASSEMBLY through the hole where the CYCLE SOLENOID

was.

Installing the AUTO-FOCUS BRACKET ASSEMBLY

[1] Do the replacement procedure for the AUTO-FOCUS BRACKET ASSEMBLY in reverse order.

Replacing the CAM STACK ASSEMBLY and CYCLE LEVER ASSEMBLY

Warning

Dangerous Voltage

[1] Disconnect the main power.

[2] Do the replacement procedure for the MECHANISM ASSEMBLY.

[3] Remove the INDEXER LEVER ASSEMBLY from the TOP PLATE of the MECHANISM ASSEMBLY.

[4] Remove the

Torx SCREW from the WORM PULLEY ASSEMBLY.

[5] Remove the WORM PULLEY ASSEMBLY.

[6] Remove the DIRECTION LEVER LINK from the DIRECTION LEVER.

A091_4023BA

SOLENOID

CYCLE

SCREW

ASSEMBLY

BRACKET

FOCUS

AUTO

SCREW (2)

SCREW

A091_4023BCA

PULLEY

WORM