Focus malfunctions – Kodak 4600 User Manual

Page 48

Advertising
background image

SERVICE MANUAL

48

18NOV97 – SM5440-1

Focus Malfunctions

TIMER does not operate

1. Check the VARIABLE RESISTOR for

correct operation and install a new part if
necessary.

2. Move the TIMER BUTTON forward and

backward; use a DVM to check for changes
in W.

3. Energize the projector and move the TIMER

to “S”.

• Check the voltages on CR3, Q3, and

Q4, see the voltage table.

DARK SHUTTER SWITCH does not operate

1. Energize the projector and release the

DARK SHUTTER to allow projection.

2. Check for continuity between PINS 4 and 5

on the SPECIAL APPLICATIONS PLUG.

3. Press the “FORWARD” or “REVERSE”

BUTTONS to close the DARK SHUTTER.

4. In the closed position, the DVM should

measure 0 W.

5. If this procedure does not correct the

malfunction, install a new DARK SHUTTER
SWITCH.

After the FOCUS MOTOR energizes and
moves, the FOCUS MOTOR oscillates.

1. Remove R3 and install a new 68K W 1/4 W

RESISTOR (part 220040).

2. If there is still a malfunction, install a new

PHOTOCELL.

Malfunction

Check

No manual focus

1. Check the FOCUS SHAFT SPRING for the

correct tension.

2. Check the LENS SUPPORT SPRING for

correct tension.

3. Check the LENS DRIVE GEAR on the

FOCUS SHAFT ASSEMBLY for damage
and install a new part if necessary.

No remote focus (Non Auto Focus models)

1. Check the REMOTE CORD for damage;

use a REMOTE CORD that has no
damage.

2. Actuate and hold the REMOTE CONTROL.

3. Check that the voltage across the FOCUS

MOTOR is 6.7 V AC. If the voltage is
correct, install a new FOCUS MOTOR.

4. Check that the secondary voltage on the

MAIN MOTOR is correct.

Malfunction

Check

Advertising