background image

Diagnostics

SM5440-1 – 18NOV97

45

Voltage Specifications - General Parts

Power, Illumination, and Cooling Malfunctions

Part

Procedure

Voltage

FOCUS MOTOR

------

6.7 V AC

CYCLE SOLENOID

Press the REVERSE
BUTTON.

39 W, 10 V DC

RACK SOLENOID

------

39 W, 10 V AC

LAMP RECEPTACLE

------

Standard Models:
82 V AC, approximately 85-86
V AC without a LAMP
MODULE installed

Long Life Models:
74 V AC, 76 V AC without
LAMP

DROPPING RESISTOR

Move to the LO LAMP
position.

3.0 W, 10.4 V AC drop across

Malfunction

Check

The MOTOR does not operate.

1. Check the continuity across the THERMAL

FUSE ASSEMBLY, and MOTOR FUSE.

2. Check that the primary voltage on the MAIN

MOTOR is correct.

3. Check that the voltage on POWER

SWITCH is correct.

The FAN does not operate, MOTOR operates.

1. Check that the FAN BELT is not broken.

2. Check and remove obstructions in the FAN

area.

There is excessive noise in the FAN.

1. Check and remove obstructions in the FAN

area.

2. Check that the tension is correct on the

FAN BELT.

3. Check that the FAN BELT is clean.

4. Check the condition of the BEARING in the

FAN ASSEMBLY.

The LAMP does not operate.

1. Check the LAMP for damage.

2. Check the LAMP RECEPTACLE

3. Check the LAMP TERMINAL ASSEMBLY

in the LAMP MODULE ASSEMBLY for
damage.

There is an obstruction in the light path.

1. Check the DARK SHUTTER for correct

operation. See the adjustment for the
DARK SHUTTER.

2. Check the LIGHT BAFFLE in the

MECHANISM for damage; it should not
cause a jam in the SHUTTER.

Advertising