background image

Adjustments

SM5440-1 – 18NOV97

31

Warning

Dangerous Voltage

[4] Energize the projector.

[5] Set the projector to the LO-LAMP position.

[6] Install and hold the AUTO FOCUS TARGET

SLIDE TL-3002 until it is fully seated in the GATE
MECHANISM.

[7] Look through the PROJECTION LENS hole and

observe the focus light path on the AUTO-FOCUS
TARGET SLIDE TL-3002. Check that the light
path is correct. If not, do the adjustment
procedure for the FOCUS LIGHT PATH.

Warning

Dangerous Voltage

[8] Disconnect the main power.

[9] Heat the 2 POSTS on the PHOTOCELL

HOUSING to allow the POSTS to bend enough to
pull the PHOTOCELL CIRCUIT BOARD up and
off the PHOTOCELL HOUSING. Use a
SOLDERING IRON.

[10] Remove the 2 Wratten FILTERS and the

PHOTOCELL MASK.