To edit an entire wash cycle formula, Wash 1 – wash 4 – Alliance Laundry Systems UW35B2 User Manual

Page 15

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Programming

13

F232168

To Edit an Entire Wash Cycle
Formula

Enter Program Mode. Press the (

∧) key until display

shows “CY01”.

Press the (

∧) or (∨) key until cycle to be edited is

displayed; then press START key to select the cycle
desired. Refer to Figure 1, showing which cycle
number corresponds to each key when in Run Mode.

Agitation for the Cycle

With display showing “CY_x” (x = cycle number),
press the START key. Display shows either “nor

n

(for normal agitation), or “GEnt” (for gentle agitation).
Press the (

∧) or (∨) key to alter the selection, or the

START key to continue. Each cycle can be set up for
Normal agitation (12 seconds forward, 3 seconds
pause, 12 seconds reverse, 3 seconds pause, repeat) or
Gentle agitation (3 seconds forward, 12 seconds pause,
3 seconds reverse, 12 seconds pause, repeat).

Wash 1 – Wash 4

NOTE: Programming a time other than “00” for
Wash 1 will make the WASH indicator LED light
while this step is running, but NOT in Program
Mode.

The main display shows “USH1” indicating you are in
the Wash segment (number will reflect selected Wash
segment 1-4), otherwise wash segments are identical.
Press START key. Display shows agitation time during
the step: “00” (skips segment) or 2-30 minutes. Wash
2 agitation’s time can be 2-20 minutes, 2-15 minutes
for Wash 3 and Wash 4, or “00” to skip Wash 2, Wash
3, or Wash 4. This is the time after the fill and before
the drain and does not include spin time or time to first
reach a programmed temperature (if your machine is
configured for heat). Press the (

∧) or (∨) key to alter

the selection, or the START key to continue.

Display shows “CFIL”, “HFIL”, “bFIL” (for cold, hot,
or warm [both]) or “EFIL”. Press the (

∧) or (∨) key to

alter the selection, or the START key to continue.

NOTE: Extra Fill (“EFIL”) possible only if
configured for “EFIL” in Setup Mode. If
configured, a third fill valve can be controlled.

Display shows “LO”, “

n

Ed”, or “HI” for low, medium,

or high water level, respectively. Press the (

∧) or (∨)

key to alter the selection, or the START key to
continue.

Display shows “SUP0”, “SUP1”, “SUP2”, “SUP3”,
“SUP4”, “SUP5” (extra supply), “SUP6”, or “SUP7”
(supply 4 and extra supply together), indicating no
supply, supply 1, supply 2, supply 3, supply 4, supply
5 (extra supply), supply 6 (supply 1 and 2 together), or
supply 7 (supply 4 and extra supply 5 together). Press
the (

∧) or (∨) key to alter the selection, or the START

key to continue.

NOTE: “SUP5” and “SUP7” appear ONLY if
control is configured for “ESUP” (spare output set
up to operate as an EXTRA supply signal for
external chemical) in Setup Mode. If the alternate
function for the spare output is selected (“EFIL”),
the output will function as an additional fill valve
signal with a programmable water level. In this
case, extra supply function would NOT be
available.

NOTE: If programmed for “SUP2”, the ADD
BLEACH indicator LED light turns on and if set
up for “bEEP” (refer to Setup Mode
section) the
buzzer sounds for the first 8 seconds that supply 2
is on.

Press the (

∧) or (∨) key to alter the selection or START

key to continue.

The washer-extractor has 5 supply compartments,
designated as compartments 1, 2, 3, 4 and 5.
Compartment 1 is farthest to the rear of machine.
Moving toward the front of machine, compartments
are ordered 2, 3, 4 and 5 (at the front of machine).
Supply signals 1 through 5 correspond to
compartments 1 through 5. Supply signals 1, 2, and 3
have dedicated water valves that flush compartments
1, 2 and 3 (along with the signal being available for
external supplies). Supply signal 4 operates a valve
that flushes compartment 4. The supply signal is
available for external supply connection. This valve is
connected so that it also flushes supply compartment 5
when the supply 4 signal is on. For example, if supply
4 signal is programmed, it will flush compartments 4
and 5. Supply 5 is available to operate an external
supply.

NOTE: For additional assistance, refer to
installation instructions.

Advertising