Programming

F232168

18

Permanent Diagnostic Test Cycle

Control Test

Warm fill to low water level

Display flashes “bFIL”/“LO” (WASH LED on), no agitation

Outputs: Motor OFF, Drain closed, hot fill on, cold fill on

Pause after reaching low water
level

Display shows “LO” (no flashing), LOW water level dot ON, no agitation (keypad WASH
LED on); pauses until operator presses

(

∧)

key

Outputs: Motor OFF, Drain closed

Drain (can advance to next step
by pressing

(

∧)

key here)

Display shows “drAI”, no agitation (keypad WASH LED on)

Outputs: Motor OFF, Drain open

Cold fill to medium level

Display flashes “CFIL”/“

n

Ed” (keypad WASH LED on), no agitation.

Outputs: Motor OFF, Drain closed, cold fill on

Pause after reaching medium
water level

Display shows “

n

Ed” (no flashing), LOW and MEDIUM water level dots ON no agitation

(keypad WASH LED on); pauses until operator presses

(

∧)

key

Outputs: Motor OFF, Drain closed

Hot fill to high level

Display flashes “HFIL”/“HI” (keypad WASH LED on), no agitation.

Outputs: Motor OFF, Drain closed, hot fill on

Pause after reaching high water
level

Display shows “HI” (no flashing), LOW, MEDIUM, and HIGH water level dots ON, no
agitation (keypad WASH LED on); pauses until operator presses

(

∧)

key

Outputs: Motor OFF, Drain closed

Heat to 110°F (45°C)
SKIPS THIS STEP

if machine

does not have heat capability
(“noHt” selected in Setup
Mode)

Display flashes “HEAt” and the temperature inside the machine while agitating in forward
and reverse; continues until temperature reaches 104°F (40°C), then advances to next step.
(keypad WASH LED on)

Outputs: Motor alternates forward 12 seconds, off 3, reverse 12 seconds, off 3 seconds
and repeats; Drain closed; Heat ON UNTIL 104°F (40°C) reached

Extra supply / fill spare –
5 seconds (depends on setup)

Display flashes ‘ESUP’ / ‘EFIL’ (keypad WASH LED on)

Outputs: Motor alternates forward 12 seconds, off 3, reverse 12 seconds, off 3 seconds
and repeats; Drain closed; ‘AF’ output ON.

Supply 1: 5 seconds (Heat
signal also on (IF at least low
water level – verifies output
even if not heated model)

Display shows ‘SUP1’ (keypad WASH LED on)

Outputs: Motor alternates forward 12 seconds, off 3, reverse 12 seconds, off 3 seconds
and repeats; Drain closed; Supply 1 ON, HT ON, cold fill ON

Supply 2: 5 seconds (Heat on
also)

Display shows ‘SUP2’ (keypad ADD BLEACH LED on)

Outputs: Motor alternates forward 12 seconds, off 3, reverse 12 seconds, off 3 seconds
and repeats; Drain closed; Supply 2 ON, HT ON, cold fill ON

Supply 3: 5 seconds (Heat on
also)

Display shows ‘SUP3’ (keypad RINSE LED on)

Outputs: Motor alternates forward 12 seconds, off 3, reverse 12 seconds, off 3 seconds
and repeats; Drain closed; Supply 3 ON, HT ON, cold fill ON

Supply 4: 5 seconds

Display shows ‘SUP4’ (keypad RINSE LED on)

Outputs: Motor alternates forward 12 seconds, off 3, reverse 12 seconds, off 3 seconds
and repeats; Drain closed; Supply 4 ON, cold fill ON

Pause 5 seconds, then Forward
wash speed – 60 seconds

Display shows ‘For’

Outputs: Motor operates wash speed forward; drain closed

Table 2 (Continued)

Advertising